Original Research Article | OPEN ACCESS

Reverse Phase High Pressure Liquid Chromatogra-phic Determination of Rifampin Quinone and Hydra-zone in Anti-tuberculosis Fixed-Dose Formulations Containing Sodium Ascorbate as Anti-oxidant

P Umapathi , J Ayyappan, Darlin Quine

Department of Analytical Research and Development, Micro Labs Ltd, 67/68-A, Third Phase, Peenya Industrial Area, Bangalore 560 058, India;

For correspondence:-  P Umapathi   Email: umpy04@yahoo.com   Tel:+918028379197

Received: 11 June 2010        Accepted: 17 October 2010        Published: 23 December 2010

Citation: Umapathi P, Ayyappan J, Quine D. Reverse Phase High Pressure Liquid Chromatogra-phic Determination of Rifampin Quinone and Hydra-zone in Anti-tuberculosis Fixed-Dose Formulations Containing Sodium Ascorbate as Anti-oxidant. Trop J Pharm Res 2010; 9(6):587-593 doi: 10.4314/tjpr.v9i6.10

© 2010 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To establish the method for the analysis of rifampin quinone and hydrazone in fixed-dose combination tablets (FDC) containing rifampicin with or without sodium ascorbate as an additive.  
Methods:  The International Pharmacopoeial (IP) method for the estimation of rifampin quinone in FDC was modified. The extraction solvent (methanol/buffer mixture) of the IP method was replaced with ethyl acetate, in order to stabilize rifampin quinone in sample solutions of FDC containing sodium ascorbate as an ingredient.
Results:  Rifampin quinone in FDC samples containing sodium ascorbate, which is not detectable in the IP method, was found to be 1.15 % (4-FDC), 1.52 % (3-FDC) and 1.60 % (2-FDC) using the modified method.  Recovery of rifampin quinone in spiked samples of FDCs was practically nil in IP method whereas the recovery was 99.95%, 99.39 and 99.02 % for 4–FDC, 3-FDC and 2-FDC, respectively.
Conclusion: This modified method was suitable for the determination of rifampin quinone in fixed-dose formulations of rifampin both in the presence and absence of sodium ascorbate. The method is specific, precise, accurate, robust, rugged and gives a linear response for the quantitative estimation of rifampin quinone and hydrazone in fixed-dose combination tablets containing rifampin.

Keywords: Fixed dose combination; Rifampin quinone; Tuberculosis; Sodium ascorbate; Quantitative determination; HPLC

Impact Factor
Thompson Reuters (ISI): 0.523 (2021)
H-5 index (Google Scholar): 39 (2021)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3,   4
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates